Repeater Controller Troubleshooting
From Link Communications - Support
Contents |
[edit] DTMF Decoders
See Troubleshooting DTMF Decoders.
[edit] Autopatches (Telephone Interconnects)
See Troubleshooting Autopatches.
[edit] Serial Ports
See Serial Port Interfacing and Serial_Port_Troubleshooting
[edit] COR and PL Detect Inputs
See Troubleshooting_COR_and_PL_signals
[edit] Looses Settings When Power Disconnected
- RLC-1 doesn't have a battery, so that can't be the problem.
- RLC-2, RLC-4, RLC-5:
- Replace the Dallas RAM module (it has a battery inside).
- If ramping the power supply voltage up slowly on startup makes it loose settings, replace the reset chip (DS-1232 or DS-1233)
- RLC-Club, RLC-3:
- Check battery (should be at least 2.8V, new batteries run from 3.0 to about 3.3V).
- Check for voltage at the RAM chips (pin 32).
- Power to the RAM chips should be supplied by the DS-1221 (or equivalent).
[edit] Temperature Sensors
[edit] Audio Delay Modules
[edit] RLC-1 Plus Serial TX Modification
On some older RLC-1 Plus controllers, the serial data from the controller to the computer gets messed up (strange characters, etc). See RLC-1 Plus Serial TX Modification for a simple modification that may help.
[edit] Known Firmware Bugs
See Known Firmware Bugs.